Bipolar circuit breaker
This bipolar circuit breaker is according to the EN 60934 standard and meets the NF F 62-001 standard (railway rolling stock) only for the AN and AS curves.
The most frequent uses for this circuit breaker are protection :
- Single phase alternating current circuits PHASE + NEUTRAL (230 Volts 50/60 Hz)
- PHASE + PHASE circuits (400 Volts 50/60 Hz)
Other applications of the bipolar diruptor :
- In direct current (up to 150 Volts per pole according to models)
- In protection of 2 different circuits, 2 poles can have different curves (thermal, also thermal-magnetic or pure magnetic) and different sizes (from 0.04 to 50 Amps)
- In remote tripping control through one pole.
Different mounting and fixing possibilities (more information below technical specifications)
↓
Reference | Designation |
7212101 7.5C84 | DISJ. DIRUPTOR BI MT 7.5A/D |
7212101.5C | DISJ. DIRUPTOR BI MT 0.5A/D |
7212104 10D | DISJ. DIRUPTOR BI MT 10A/D |
7212104 16D | DISJ. DIRUPTOR BI MT 16A/D |
7212104 20D | DISJ. DIRUPTOR BI MT 20A/D |
7212104 3D | DISJ. DIRUPTOR BI MT 3A/D |
7212204 2AN84 | DISJ. DIRUPTOR BI MT 2A |
7217402 15D | DISJ. DIRUPTOR BI MT 15A/D |
7220707 16D | DISJ. DIRUPTOR BI MT 16A/D |
7220707 25D | DISJ. DIRUPTOR BI MT 25A/D |
7220707 2T8420 | DISJ. DIRUPTOR TRI TH 2.4A |
7220707 3T8420 | DISJ. DIRUPTOR BI TH 3A |
7220707 40D | DISJ. DIRUPTOR BI MT 40A/D |
72207071.5T0.5 | DISJ. DIRUPTOR BI T 1.5 |
7220FS1892/2.5 | DISJ. DIRUPTOR BI TH 2,5A |
7220FS1892/3 | DISJ. DIRUPTOR BI TH |
7221101 2T84 | DISJ. DIRUPTOR BI TH 2A |
72211011.2T84 | DISJ. DIRUPTOR BI TH 1.2A |
7221104 10D | DISJ. DIRUPTOR BI MT 10A/D |
7221104 10D10 | DISJ. DIRUPTOR BI MT 10A/D |
7221104 15T | DISJ. DIRUPTOR BI TH 15A |
7221104 16D | DISJ. DIRUPTOR BI MT 16A/D |
7221104 1C10 | DISJ. DIRUPTOR BI MT 1A |
7221104 3DXW19 | DISJ. DIRUPTOR BI MT 3A/D |
7221109 10D | DISJ. DIRUPTOR BI MT 10A/D |
7221109 3D19 | DISJ. DIRUPTOR BI MT 3A/D |
7221109 4D19 | DISJ. DIRUPTOR BI MT 4A/D |
7221204 5T80 | DISJ. DIRUPTOR BI TH 5A |
7222101 10T8447 | DISJ. DIRUPTOR BI TH 10A |
7222101 16T8447 | DISJ. DIRUPTOR BI TH 16A |
7222101 2T8447 | DISJ. DIRUPTOR BI TH 2A |
7222101 3C8447 | DISJ. DIRUPTOR BI MT 3A |
7222101 3T8447 | DISJ. DIRUPTOR BI TH 3A |
7222101 5CHP58 | DISJ. DIRUPTOR HP BI MT 5A/C |
7222104 10C | DISJ. DIRUPTOR BI MT 10A/C |
7222104 10D | DISJ. DIRUPTOR BI MT 10A/D |
7222104 10D10 | DISJ. DIRUPTOR BI MT 10A/D |
7222104 10T | DISJ. DIRUPTOR BI TH 10A |
7222104 10T46 | DISJ. DIRUPTOR BI TH 10A |
7222104 12D | DISJ. DIRUPTOR BI MT 12A/D |
7222104 15T | DISJ. DIRUPTOR BI TH 15A |
7222104 16D | DISJ. DIRUPTOR BI MT 16A/D |
7222104 16D41 | DISJ. DIRUPTOR BI MT 16A/D |
7222104 16T | DISJ. DIRUPTOR BI TH 16A |
7222104 20D | DISJ. DIRUPTOR BI MT 20A/D |
7222104 20D41 | DISJ. DIRUPTOR BI MT 20A/D |
7222104 20D75 | DISJ. DIRUPTOR BI MT 20A/D |
7222104 20T | DISJ. DIRUPTOR BI TH 20A |
7222104 2C | DISJ. DIRUPTOR BI MT 2A/C |
7222104 2T | DISJ. DIRUPTOR BI TH 2A |
7222104 3D | DISJ. DIRUPTOR BI MT 3A/D |
7222104 4C | DISJ.DIRUPTOR BI MT 4A/C |
7222104 4D | DISJ. DIRUPTOR BI MT 4A/D |
7222104 5D | DISJ. DIRUPTOR BI MT 5A/D |
7222104 6C | DISJ.DIRUPTOR BI MT 6A/C |
7222104 6D | DISJ. DIRUPTOR BI MT 6A/D |
7222104 6DUL | DISJ. DIRUPTOR BI MT 6A/D |
7222104 7.5D | DISJ DIRUPTOR BI MT 7,5A |
7222104 8D | DISJ. DIRUPTOR BI MT 8A/D |
7222104.60D | DISJ.DIRUPTOR BI MT 0.6A |
7222109 2T80 | DISJ. DIRUPTOR BI TH 2A |
7222109 5AN | DISJ. DIRUPTOR BI MT 5A |
7222204 10AN | DISJ. DIRUPTOR BI MT 10A |
7222204 10AS | DISJ. DIRUPTOR BI MT 10A |
7222204 10T80 | DISJ. DIRUPTOR BI TH 10A |
7222204 16AN | DISJ. DIRUPTOR BI MT 16A |
7222204 16AS | DISJ. DIRUPTOR BI MT 16A |
7222204 16T80 | DISJ. DIRUPTOR BI TH 16A |
7222204 1AN | DISJ. DIRUPTOR BI MT 1A |
7222204 1AN81 | DISJ. DIRUPTOR BI MT 1A |
7222204 1T80 | DISJ. DIRUPTOR BI TH 1A |
7222204 20AS | DISJ. DIRUPTOR BI MT 20A |
7222204 25AS | DISJ. DIRUPTOR BI MT 25A |
7222204 25D | DISJ. DIRUPTOR BI MT 25A/D |
7222204 25T90 | DISJ.DIRUPTOR BI TH 25A |
7222204 32AS | DISJ. DIRUPTOR BI MT 32A |
7222204 32T | DISJ. DIRUPTOR BI TH 32A |
7222204 3AN | DISJ. DIRUPTOR BI MT 3A |
7222204 45T | DISJ BIPOLAIRE 45A T |
7222204 5AN | DISJ. DIRUPTOR BI MT 5A |
7222204 5AS | DISJ. DIRUPTOR BI MT 5A |
7222204 5T80 | DISJ. DIRUPTOR BI TH 5A |
7222204 6AN | DISJ. DIRUPTOR BI MT 6A |
7222204 8AN | DISJ. DIRUPTOR BI MT 8A |
72222041.5AN | DISJ. DIRUPTOR BI MT 1.5A |
7222307 1AN81 | DISJ. DIRUPTOR BI MT 1A |
7222307 25AS | DISJ. DIRUPTOR BI MT 25A |
7222307 3AN84 | DISJ. DIRUPTOR BI MT 3A |
7222453 40D | DISJ. DIRUPTOR BI MT 40A/D |
7223402 10D84 | DISJ. DIRUPTOR BI MT 10A/D |
7223402 2C84 | DISJ. DIRUPTOR BI MT 2A/C |
7223402 4D84 | DISJ. DIRUPTOR BI MT 4A/D |
7223402 5D84 | DISJ. DIRUPTOR BI MT 5A/D |
7223402 6D84 | DISJ. DIRUPTOR BI MT 6A/D |
7223402.25C84 | DISJ. DIRUPTOR BI MT 0.25A/C |
7223402.25T84 | DISJ. DIRUPTOR BI T 0.25A |
7229109 3D82 | DISJ. DIRUPTOR BI MT 3A/D |
7229409 3D82 | DISJ. DIRUPTOR BI MT 3A/D |
Technical characteristics
NUMBER OF POLES : 2 poles
CONTROL SYSTEM : With or Without trip button “OFF”
MOUNTING :
Plug-in (20A limitation)
Flush-mounting, 2 screws on front face
Flush-mounting, threaded collar for mounting on front face
Snap on DIN asymetrical rail
Push-push, threaded collar for mounting on front face
Without fixation
Snap on DIN symetrical rail
Plug-in base for print circuit
CONNECTION :
Flush mounting models
Fast connections (male) 6,35 x 0,8 at 45° (In _ 15A)
Terminals at 60° screws with clamps for cable up to 1 x 6 mm2 (In _ 20A)
Terminals at 60°, HS M4 screws for cable up to 1 x 6 mm2 (In _ 20A)
Fast connections (male) 6,35 x 0,8 at 90°
Down pillar type terminals, transversal hole (In _ 40A)
Down pillar type terminals, longitudinal hole (In _ 40A)
Terminals, screws with clamps, 1 at 60°. 1 at 90°, for cable from 6 to 16 mm2
Snap on DIN rail models
Flat terminals, screws with clamps (In _ 20A)
Up pillar type terminals, longitudinal hole (In _ 40A)
Without fixation models
Terminals design on request
Plug-in base for print circuit
Fast connections (male) 6,35 x 0,8 at 90°
Plug-in
Pins _ 7, 20 mm between axles (série 7000)
CURVES + RAED CURRENT :
Thermal : 0,04 – 32 A
Thermal-magnetic : 0,10 – 32 A
Magnétic : 14 A eff. 20 A AC max
OPTIONS :
Auxiliary contacts NC
Auxiliary contacts NO
Auxiliary contacts changeover
Special contacts for high peak of current, (thermal release only)
Temperature compensation (thermal 2 to 30A, thermal-magnetic 3 to 20A)
Special adjustment for magnetic release
Red push button “ON”
Knurled nut and counter nut for drilling 14,5 mm
Power contacts delivered with shunt
U.L 1077. Recognized
Diruptor 230/400 VAC with 6 kA/AC short circuit capacity
D.C. Diruptor : one pole rated 110/125 V DC or 2-poles 110/125 V DC per pole
Reinforced tropicalization
Magnetic release only “all or nothing”
Individual checking (with tests report)
Change of temperature class (adjustment at 60° C)
Rated current marked on base (beside screw for adjustment)
Rated current marked on push-button “ON”, at the top or at the bottom
One pole rated 72 V DC max. nominal (90V test) 230 V AC or multipole 400 V AC